File Format
Name Tandy 200 BASIC tokenized file
Ontology
Released 1984

Tandy 200 BASIC was a version of Microsoft BASIC for the Radio Shack Tandy 200 computer. The tokenizations for the TRS-80 Model 100 and Tandy 102 appear to be identical. The NEC PC-8201/8300 format is not the same, but should be similar.

Contents

Tokens

Table of tokenized BASIC keywords.

Hex Dec Token meaning Notes
80 128 END
81 129 FOR
82 130 NEXT
83 131 DATA
84 132 INPUT
85 133 DIM
86 134 READ
87 135 LET
88 136 GOTO
89 137 RUN
8A 138 IF
8B 139 RESTORE
8C 140 GOSUB
8D 141 RETURN
8E 142 REM
8F 143 STOP
90 144 WIDTH
91 145 ELSE When tokenizing, the Tandy 200 always adds a colon (':') before the ELSE token (3A 91). If the user actually writes :ELSE it is tokenized as 3A 3A 91.
92 146 LINE
93 147 EDIT
94 148 ERROR
95 149 RESUME
96 150 OUT
97 151 ON
98 152 DSKO$
99 153 OPEN
9A 154 CLOSE
9B 155 LOAD Note that LOADM is simply the token for LOAD followed by an ASCII 'M'.
9C 156 MERGE
9D 157 FILES
9E 158 SAVE
9F 159 LFILES
A0 160 LPRINT
A1 161 DEF
A2 162 POKE
A3 163 PRINT
A4 164 CONT
A5 165 LIST
A6 166 LLIST
A7 167 CLEAR
A8 168 CLOAD
A9 169 CSAVE
AA 170 TIME$
AB 171 DATE$
AC 172 DAY$
AD 173 COM
AE 174 MDM
AF 175 KEY
B0 176 CLS
B1 177 BEEP
B2 178 SOUND
B3 179 LCOPY
B4 180 PSET
B5 181 PRESET
B6 182 MOTOR
B7 183 MAX
B8 184 POWER
B9 185 CALL
BA 186 MENU
BB 187 IPL
BC 188 NAME
BD 189 KILL
BE 190 SCREEN
BF 191 NEW
C0 192 TAB(
C1 193 TO
C2 194 USING
C3 195 VARPTR
C4 196 ERL
C5 197 ERR
C6 198 STRING$
C7 199 INSTR
C8 200 DSKI$
C9 201 INKEY$
CA 202 CSRLIN
CB 203 OFF
CC 204 HIMEM
CD 205 THEN
CE 206 NOT
CF 207 STEP
D0 208 +
D1 209 -
D2 210 *
D3 211 /
D4 212 ^
D5 213 AND
D6 214 OR
D7 215 XOR
D8 216 EQV
D9 217 IMP
DA 218 MOD
DB 219 \
DC 220 >
DD 221 =
DE 222 <
DF 223 SGN
E0 224 INT
E1 225 ABS
E2 226 FRE
E3 227 INP
E4 228 LPOS
E5 229 POS
E6 230 SQR
E7 231 RND
E8 232 LOG
E9 233 EXP
EA 234 COS
EB 235 SIN
EC 236 TAN
ED 237 ATN
EE 238 PEEK
EF 239 EOF
F0 240 LOC
F1 241 LOF
F2 242 CINT
F3 243 CSNG
F4 244 CDBL
F5 245 FIX
F6 246 LEN
F7 247 STR$
F8 248 VAL
F9 249 ASC
FA 250 CHR$
FB 251 SPACE$
FC 252 LEFT$
FD 253 RIGHT$
FE 254 MID$
FF 255 ' (QUOTE) When tokenizing, the single quote character expands to three characters: a colon (3A), the byte for REM (8E), and then FF.

File Format

Tokenised BASIC code is a sequence of tokenized lines. Each tokenized line has the following format:


Format of a single tokenized line
Name Length Description
PL PH 2 bytes Address in RAM of the next line of BASIC; unsigned 16-bit integer, little-endian. PL PH equal to zero marks the end of a tokenized BASIC listing. All other values can be ignored as they are merely placeholders in the file. During program load, Tandy BASIC always recalculates PL PH. Once in memory, PL PH is used to skip to the line required for GOTO, GOSUB, and READ, thus speeding up the program.
LL LH 2 bytes Line number; unsigned 16-bit integer, little-endian.
B0 … Bn Any number Sequence of tokens or ASCII characters. If a character's value is ≥ 128, then it is a token. All tokens are a single byte.
NULL 1 byte NULL byte (0x00) to signal end of line.

The end of the tokenized data is signaled by two consecutive NULLs in the location where PL PH would normally begin a new line.

Limits

  • Line numbers can range from 0 to 65529 (but see variances below).
  • Tokenized line length is limited to 256 characters, including the trailing NULL byte. (To do: double check this.)

Acceptable variances

While Tandy BASIC will never generate such files, it has no problem loading a tokenized program that:

  • Has line numbers out of order; they will be sorted when loaded.
  • Contains duplicate line numbers; previous line is discarded.
  • Contains arbitrary bytes for PL PH; they are always regenerated during loading.
  • Has a ^Z (ASCII 26) at the end of the file.
  • Contains illegal line numbers; this can be used to store hidden binary data according to John R. Hogerhuis.

Note that while these variances are accepted on an actual Model T device (Model 100, Tandy 200, or Tandy 102), emulators may not be able to handle such files. For example, the Virtual T emulator (as of version 1.7 in 2022) refuses to load tokenized BASIC programs that have lines out of order, duplicate lines, or bogus values for PL PH.

Details for PL PH

(Stub. This is where the correct calculation of PL PH values will go.)

Format documentation

Other links

Personal tools
Namespaces

Variants
Actions
Navigation
Toolbox